TEEJET SPRAY TIP CALIBRATION
BA6D & BA8D
All standard booms come w/ 8003VP poly tips.
Formula: GPA x MPH x Nozzle Spacing
5940
Example: 20gpa x 4mph x 20” = 1600
= .27gpm
5940 5940
Take the GPM that you figured & look down the GPM chart to figure what pressure you need to run at that desired
speed.
*NOTE: If spraying liquid nitrogen you will need to multiply the conversion factor w/ the gpa, mph, & nozzle
spacing.
Conversion Factor: 28% Nitrogen - 10.65 lbs. per gal. - 1.13
32% Nitrogen - 11.00 lbs. per gal. - 1.15
Ex. 20gpa x 4mph x 20” x 1.13 = 1808
= .31gpm
5940 5940